CNA Cardiac (Monitoring)
Additional Ratings
Description
Cares for patient with continuous cardiac monitoring
Behavioral Criteria
Placing Electrodes on Patient:
Prep skin: select a flat, non-muscular area, Clean skin , Remove hair using clippers ( do not use a razor)
Apply electrodes- 5 lead
White "Right" (Directly below the clavicle and near the Right shoulder)
Black- "Smoke over fire" (Directly below the clavicle and near the Left shoulder) )
Red- "Fire under Smoke" (Left Lower abdomen)
Green- (Right Lower abdomen)
Brown- ( On the 4th intercostal space at the right sternal border)
Changes electrodes daily or more often, if needed to prevent irritation
Assist in changing batteries when directed by nurse
Report abnormal findings or alarms to nurse
Evidence of Achievement
Direct observation of competency in all areas through patient care or simulation / case study; documentation in electronic health record accurate and complete
References
Toolbox (Policy/Procedure)
Cardiac Telemetry Monitoring
Toolbox: How to Guides to Technology Systems & Devices
Critical Care Nursing Clinics of North America. (2006). Practice Standards for ECG Monitoring in Hospital Settings: Executive summary and Guide for Implementation
Heart Lung. (1991). Electrode Site Preparation Techniques: A Follow Up Study.